#392: Verification and Validation in MedTech: A Practical Guide with Devon Campbell

Global Medical Device Podcast · 22 Nov 2024 · 58m · Episode 392

What this episode covers

Devon Campbell, a medical device consultant, explains the critical distinctions between verification (did we build the product right?) and validation (did we build the right product?) for early-stage medtech companies. He emphasizes that strong, testable user needs and design inputs are prerequisites for successful V&V, warning that weak requirements lead to validation failures. Campbell advocates for pre-verification testing to refine protocols and manage sample sizes, ensuring that design reviews and traceability are robust before formal regulatory submission.

Other shows on the same ground, closest first.

  • Being an Engineer · 43m

    Dakota Welker | User Needs, Design Inputs, Verification & Validation

    Dakota Welker, founder of Think MedTek, explains his four-phase product development methodology for medical device startups, emphasizing user needs, design inputs, verification, and validation. He details how he rescues stalled projects by clarifying scope and documentation, and describes a specific case where bringing manufacturing in-house and negotiating with multiple vendors reduced costs by 50%. Welker also discusses his transition from automotive and pneumatics to medical devices, his focus on CFD tools like Simscale, and the importance of balancing engineering rigor with client communication.

  • The Pragmatic Embedded Podcast · 50m

    Requirements Engineering, part 2: A Practical Process for Safety-Critical Development

    Jeff Gable and Luca engineer discuss a rigorous process for requirements engineering in safety-critical development, particularly for medical devices. They distinguish between prototyping (technical feasibility) and MVPs (market viability), emphasizing that design-controlled requirements must be minimal yet comprehensive, including extensive error handling. The hosts advocate for writing test cases alongside requirements, tracking requirements completion for honest project status, and using 'tracer bullets' to reduce uncertainty early in implementation.

  • Let's Combinate · 21m

    157 - Design Inputs that Don't Suck, Risk Control Measures and Problems with Verification with Chuck Ventura

    Chuck Ventura, founder of Ventura Solutions and CEO of HemoTek, explains why poor design inputs are a primary cause of delayed product development and verification failures in medical device and combination product projects. He advocates for spending 30% of project time on design inputs using concurrent engineering, where systems engineers collaborate with verification teams early to define clear acceptance criteria. Ventura also clarifies the structural relationship between user needs, risk controls, and design inputs, arguing that risk controls should serve as parent requirements to design inputs to ensure traceability and effective risk management.

  • Product Startup · 23m

    104: Medical Device Certification vs Wellness Device

    Bryon Bhagwandin, a medical device entrepreneur with a PhD from the University of Washington, explains the critical differences between wellness and medical devices, emphasizing that medical clearance allows sales into clinical settings. He details the three pillars of medical certification: safety, efficacy (verification and validation), and manufacturing consistency, noting that hand-built prototypes cannot be certified without statistical proof of uniform production. Bhagwandin advises that while wellness devices are cheaper to launch, starting with a medical device strategy is often superior because it opens higher-margin B2B channels and allows for easier transition to consumer markets. He also suggests that founders can leverage user data from existing wellness products to support the regulatory submission of a redesigned medical version, provided they maintain rigorous quality and avoid feature creep.

  • Product Startup · 29m

    074: Medical Device Product Development Best Practices

    Rob Crowder, Head of Product at Nutromics, explains how his team uses user journey mapping to navigate the complexities of developing medical sensor devices, specifically the Neutromics wearable patch. He details the process of validating unmet needs in high-stakes areas like therapeutic drug monitoring for vancomycin, emphasizing the need to focus on specific indications like bacteremia to ensure clinical utility and commercial viability. Crowder contrasts this rigorous MedTech evidence bar with general product development, highlighting the importance of identifying all stakeholders—patients, clinicians, and payers—early in the design phase to avoid feature creep and resource burnout.

The summary, chapters and topics are generated from the episode’s audio by this directory, not written by Global Medical Device Podcast. The episode itself belongs to its publisher.