Examining FDA’s Refusal to Accept (RTA) Policy and Guidance

Global Medical Device Podcast · 27 Jul 2022 · 44m · Episode 273

What this episode covers

Mike Drues of Vascular Sciences, joined by hosts Jon Speer and Etienne Nichols, explains the FDA’s Refusal to Accept (RTA) policy, noting that approximately 60% of 510(k) submissions are rejected during administrative review due to company errors. Drues highlights that while electronic tools like eSTAR help organize submissions, they do not evaluate content quality, leading to rejections for missing sections, inconsistent labeling, or failure to use current forms. The discussion emphasizes that companies must proactively explain 'Not Applicable' sections and treat the FDA as a customer rather than a beta tester to avoid delays.

Mentioned

Companies
FDA, Vascular Sciences, Green Light Guru
Products
510(k), De Novo, PMA
Tools
eSTAR

Other shows on the same ground, closest first.

  • Let's Combinate · 33m

    106 - FOIA, FDA Modernizing 510(k) Program, De Novo Submissions, and more databases with Michelle Lott

    Michelle Lott, founder of leanRAQA, explains how to navigate eight FDA databases, including using FOIA requests to access redacted 510(k) summaries and reviewing 483 and Warning Letter databases to identify regulatory trends. She details the recent modernization of the 510(k) program, specifically new guidance on predicate selection and clinical data, and contrasts the 510(k) pathway with the De Novo process for novel devices. Lott also outlines the Pre-Submission and 513(g) classification processes, noting their timelines and costs, while advising companies to monitor draft guidance documents to anticipate FDA expectations during submissions.

  • Let's Combinate · 22m

    077 - 8 Databases and How To Use Them with Michelle Lott

    Michelle Lott, founder of leanRAQA, walks through eight critical FDA databases for medical device regulatory strategy, including the Product Classification Database, 510(k) Database, and Registration and Listing Database. She explains how to use these tools to determine submission types, identify competitors, and access redacted technical data via FOIA requests. Lott also highlights the importance of the Guidance Document Database and the Code of Federal Regulations (CFR) for understanding specific regulatory requirements and consensus standards.

  • Let's Combinate · 1h 19m

    031 - "The Five Stages Of Regulatory Grief" with Michelle Lott

    Michelle Lott, founder of Lean RAQA, discusses her journey from large manufacturer Baxter Healthcare to consulting for small-to-mid-size medical device companies, highlighting the gap in practical regulatory strategy. She details the 'five stages of regulatory grief' clients experience when facing FDA interactions, contrasting the US 510(k) process with the rigorous, ongoing costs of EU MDR compliance. Lott also explains the nuances of regulations versus guidance documents, the QMSR harmonization, and her unique perspective as an elected industry representative on the FDA Device GMP Advisory Committee.

  • Let's Combinate · 17m

    069 - EU MDR Extension with Michelle Lott

    Michelle Lott, founder of leanRAQA, explains that the EU MDR extension is not a simple delay but a conditional pathway for companies that have actively transitioned their quality systems. She details two routes to extend certificates: submitting to national competent authorities or obtaining derogation from notified bodies, both requiring proof of effort and capacity constraints. Lott highlights that over 50% of technical files are rejected initially and notes that notified bodies are now selective, preferring clients who are prepared and easy to work with.

  • Let's Combinate · 18m

    137 - The 3 Levels of Reliability, Fault Tree Analysis, Needle Safety, Emergency Use, and Risk Management with Capt. Alan Stevens

    Capt. Alan Stevens, Global Head of Complex Devices and Drug Delivery Systems at AbbVie, and former FDA CDRH official, explains the three levels of reliability in combination products: verification data, component reliability, and system reliability. He details how Fault Tree Analysis (FTA) is used to quantify system reliability, particularly for emergency use injectors and needle safety devices, where the FDA sets specific targets like 95% or 99%. Stevens discusses the regulatory expectations for these high-risk functions and how manufacturers should determine acceptable risk levels when no specific FDA guidance exists, emphasizing the role of risk culture and design assessments.

The summary, chapters and topics are generated from the episode’s audio by this directory, not written by Global Medical Device Podcast. The episode itself belongs to its publisher.